Principles for Selecting the Location of Factory Buildings in Hunan Purification Engineering

2023-08-14 2153

Due to the high requirements for construction products in the factory purification project, the main requirements are sealing and cleanliness. So in the location selection process, it is necessary to strictly follow the site selection requirements. Choosing a good location can lay a good foundation for energy conservation in later plant purification projects.

1、 The distance between the project and the main traffic road should not be less than 50 meters.

2、 Circular fire lanes should be set up around the purification project of the factory building. If there are difficulties, fire lanes can be set up along both sides of the factory building.

3、 It should be arranged in areas within the factory area where the environment is clean and the flow of people and goods does not or rarely cross.

4、 For the location selection of factory purification projects that require micro vibration control, the vibration impact of existing vibration sources around should be measured and compared with the allowable environmental vibration values of accurate equipment and instruments.

湖南净化工程

5、 When there is a chimney on the upwind side of the high-frequency wind direction in the factory purification project, the horizontal distance between the design of Hunan Purification Engineering Company and the chimney should not be less than 12 times the height of the chimney.

6、 The road surface layer around the factory purification project should be made of materials with good integrity and low dust generation.

Hunan Purification Engineering Company

7、 Greening should be carried out around the factory purification project. Lawn can be planted, trees that do not have harmful effects on atmospheric dust concentration can be planted, and a green community can be formed. But it shall not hinder firefighting operations.

8、 Should be located in areas with low atmospheric dust concentration and good natural environment;

9、 Keep away from areas with serious air pollution, vibration, or noise interference, such as railways, docks, airports, transportation arteries, factories, warehouses, and yards that emit large amounts of dust and harmful gases. If it is not possible to stay away from severe air pollution sources, it should be located on the upwind side of the higher frequency wind direction, or on the downwind side of the lower frequency wind direction throughout the year.

Article source: Hunan Purification Engineering http://www.jmyujie.com/